Wireless sensor network performance evaluation on building with zigbee transmission

Samijayani, Octarina Nur and Muthiah, Annisa Maulidary (2018) Wireless sensor network performance evaluation on building with zigbee transmission. In: 2018 International Conference on Smart Computing and Electronic Enterprise (ICSCEE). Institute of Electrical and Electronics Engineers, Shah Alam, pp. 1-6. ISBN 978-1-5386-4838-4

[img] Text (Article's Content)
ILS0196-21_Isi-Artikel.pdf - Published Version
Restricted to Registered users only

Download (542kB)
[img] Text (Plagiarism Check)
ILS0196-21_Cek-Turnitin.pdf - Supplemental Material
Restricted to Registered users only

Download (2MB)
Official URL: https://ieeexplore.ieee.org/document/8538365

Abstract

With the growing of smart buildings, the pursuit on using the right communication technology is crucial. ZigBee as known for a low data rate, low power, and low cost wireless communication standard for building control applications, well suited for use. This leads to the problem identification which is manufacturers that indicates the ZigBee device's or XBee performance specification in a Line of Sight (LOS) setting, that it becomes difficult to indicate such performance in real indoor scenarios, with many obstacles in between transmissions. Conducting range and throughput tests are some of the ways to evaluate and analyze the XBee device's performance. Which the results show that the Received Signal Strength Indicator (RSSI) values in the LOS setting are much greater than the Non-Line of Sight (NLOS) setting. With values such as -67.8 dBm in the LOS setting, while values such as -80.54 dBm in the NLOS setting. Then for the packet loss and error results, it shows that the LOS setting has a lower rate of packet loss and error than the NLOS setting. With packet losses and error below 0.21% in the LOS setting, while in the NLOS setting the packet losses and error can be as big as 7.60%. Which also shows that the PTP network tend to have more packet losses and error than the Multi network, as much as 30 packets, even though it does have faster transmission than the Multi network, which can go as fast as 3.164 kbps. As for the LQI network, in the NLOS setting, shows that distances above 10 meters tend to be unstable and weaken. Concluding that for indoor transmissions, such as buildings, with many obstacles, the recommended operating range for the XBee device used in this research is up to 10 meters, and the recommended network is the Multi network (mesh network).

Item Type: Book Section
Additional Information: Presented in The 2018 International Conference on Smart Computing and Electronic Enterprise (ICSCEE) on 11-12 July 2018 in Shah Alam, Malaysia.
Uncontrolled Keywords: Buildings; Packet loss; ZigBee; Throughput; Meters; Performance evaluation
Subjects: 600 Applied sciences & technology > 620 Engineering
600 Applied sciences & technology > 620 Engineering > 621 Applied Physics
Divisions: Universitas Al-Azhar Indonesia (UAI) > Fakultas Sains dan Teknologi (FST) > Teknik Elektro
Depositing User: Rifda Jilan
Date Deposited: 04 Nov 2021 07:29
Last Modified: 19 Jun 2022 23:25
URI: http://eprints.uai.ac.id/id/eprint/1746

Actions (login required)

View Item View Item